Discovered Ra-226 source in Copper scrap metals


Print View Posted on: 09 March 2021

Event Date: 24 November 2020 Event Type: Radiation Source
Event Location: Iran, Islamic Republic of, Northwest border INES Rating: 1 (Final)

On 24th of November 2020, National Radiation Protection Department (NRPD) received an alarm from a radiation portal monitoring system installed in northwest border for monitoring trucks carrying imported goods.

Reported count rate from the truck loaded with copper scrap metals was 10 times of the background.

After investigation and monitoring of the scrap metals, the tip part of a lightning rod with three screwed Ra-226 sources was found. Estimated activity of each source was about 240 MBq (6.5 mCi). The tip part was transported to Iran Nuclear Waste Management Company for more analysis and management of radioactive waste.

There were no significant doses to workers or members of the public.

Estimated total activity of Ra-226 is 720 MBq (7.2 E-04 TBq). Considering D value and A/D are 4 E-02 and 1.8 E-02 respectively, it is Category 4 source.

INES Rating: 1 - Anomaly (Final)
Release beyond authorized limits? No
Overexposure of a member of the public? No
Overexposure of a worker? No

Contamination spread within the facility? No
Damage to radiological barriers (incl. fuel damage) within the facility? No

Degradation of Defence In-Depth No

Person injured physically or casualty? No
Is there a continuing problem? No

Hojatollah Salehi
Iran Nuclear Regulatory Authority (INRA)

hsalehi@aeoi.org.ir
Site Sponsors
Site Sponsors: IAEA, NEA and WANO
This site is hosted by the International Atomic Energy Agency (IAEA) and co-sponsored by the Nuclear Energy Agency of the Organization of Economic Cooperation Development (OECD/NEA) and World Association of Nuclear Operators (WANO).
Disclaimer
This site is hosted by the IAEA, however, event reports are filed and updated by authorities in participating countries, which remain responsible for all related content. Read more >