Irradiation of a worker during scheduled NNP outage at Le Blayais


Print View Posted on: 05 November 2015

Event Date: 18 August 2015 Event Type: Power Reactor
Event Location: France, BLAYAIS-4 INES Rating: 2 (Final)

On 21st August 2015, ASN was informed by EDF of the accidental exposure of a worker from an EDF contractor to a dose of ionising radiation exceeding the regulation limit.

On 18th August, during the check carried out prior to exiting the limited access area, contamination was detected on the worker’s chin. He had been carrying out maintenance work in preparation for the hydrotesting of an exchanger on the chemical and volume control system in the reactor 4 safeguard auxiliaries building in the Le Blayais NPP.

The worker was then treated by the site’s risk prevention department, which carried out a decontamination procedure, during the course of which the radioactive particle which caused the contamination was located and immediately removed. The occupational physician then evaluated the whole-body dose received and the dose on the skin of the chin.

For workers liable to be exposed to ionising radiation during their professional activities, the annual regulation dose limits are, for twelve consecutive months, 20 millisieverts for the whole body and 500 millisieverts for a 1 cm2 area of skin.

EDF’s evaluation of the dose received by the worker’s chin exceeded the regulation limit for the skin. The whole-body dose received by the worker is well below the annual regulation limit.

ASN carried out an inspection on the site on 24th August 2015. The inspectors checked that EDF and the contractor had taken all necessary steps to ensure adequate management of the incident and to analyse its causes.

INES Rating: 2 - Incident (Final) as per 28 August 2015
Release beyond authorized limits? No
Overexposure of a member of the public? No
Overexposure of a worker? Yes

Contamination spread within the facility? No
Damage to radiological barriers (incl. fuel damage) within the facility? No

Degradation of Defence In-Depth No

Person injured physically or casualty? No
Is there a continuing problem? No