United States of America, 03 Aug 2020, INES: 2

Overexposure to Worker

A radiographer and two assistants were working at an asphalt plant when a magnetic stand fell from the side of a tank and crushed a section of the guide tube of the radiography camera in use. Several attempts by the radiography crew to retract the source into the radiography camera using the crank...
Reported by Nuclear Regulatory Commission (NRC) of United States of America on 21 Dec 2020. Last update on 08 Jan 2021


Germany, 31 Jul 2020, INES: 2

Organ equivalent dose exceeding statuary annual limits

In July 2020 an incident happened at a company in Bavaria, Germany. According to the company's radiation protection supervisor, the X-ray sources of the thickness measuring system to be checked by a worker of a measurement technology company can be con-sidered as the cause of the exposure. It seems...
Reported by Gesellschaft für Anlagen und Reaktorsicherheit of Germany on 09 Feb 2021. Last update on 09 Feb 2021


Germany, 02 Jul 2020, INES: 2

Radiation exposure of a worker beyond the statuary annual dose limit

An employee of a company producing machines with integrated X-ray equipment for the determination of the basis weight was unintendedly exposed to radiation during necessary testing work. For the testing, the company concerned uses a self-made radiation protection cabinet, which is equipped with an...
Reported by Gesellschaft für Anlagen und Reaktorsicherheit of Germany on 01 Mar 2021. Last update on 01 Mar 2021


Germany, 31 Jan 2020, INES: 2

Radiation exposure of a hospital employee beyond the statuary annual dose limit

The evaluation of the OSL (Optically Stimulated Luminescence) whole-body dosimeter of a hospital employee showed a reading of 24.2 mSv. This exceeds the German statuary annual dose limit for the whole-body dose of exposed radiation personnel of 20 mSv. The person concerned showed no deterministic...
Reported by Gesellschaft für Anlagen und Reaktorsicherheit of Germany on 21 Jan 2021. Last update on 21 Jan 2021


United Kingdom, 15 Nov 2019, INES: 2

Radioisotope Manufacture Facility – Operator’s hands contaminated

The incident occurred at a cyclotron facility used to produce Flourine-18 for medical purposes. One operator was contaminated during production. Issues with the Cyclotron prompted an employee to investigate a fault resulting in contamination to the extremities. The presence of Flourine-18 on the...
Reported by Office for Nuclear Regulation (ONR) of United Kingdom on 08 Jan 2021. Last update on 08 Jan 2021